ADR provides both complete exemptions and partial exemptions that leave specific obligations in force. The main possibilities are outlined below. (ADR 1.1.3.1, 1.1.3.4 and 1.1.3.6.2, Volume I, pages 6–9.)
1. Product-specific exemptions — check these first
- Special provisions: a particular dangerous good may be wholly or partly exempt where a special provision in Chapter 3.3 expressly allows it. That provision must be assigned to the relevant entry in Table A, column (6); it is not a general exemption for all goods of the same class. (ADR 1.1.3.4.1, Volume I, page 8.)
- Limited quantities (LQ): eligible goods may use the simplified rules of Chapter 3.4 within the inner-packaging or article limit in Table A, column (7a). A value of “0” prohibits this exemption. Training, specified packaging and loading provisions, and certain tunnel requirements remain applicable. (ADR 3.4.1, Volume I, page 643.)
- Excepted quantities (EQ): eligible goods may benefit from Chapter 3.5 when its conditions are satisfied. Eligibility is indicated by Table A, column (7b); E0 means that the excepted-quantity exemption is not permitted. (ADR 1.1.3.4.3, Volume I, page 9; ADR 3.2.1, column (7b), Volume I, page 275.)
2. Exemptions based on the purpose of the transport
| Situation |
Main conditions |
| Private individuals |
Goods must be for personal, domestic, leisure or sporting use, normally packaged for retail sale, with leakage prevented. For flammable liquids in refillable receptacles filled by or for an individual, the limits are 60 litres per receptacle and 240 litres per transport unit. The exemption also covers qualifying household waste under the specified conditions. (ADR 1.1.3.1(a), Volume I, page 6.) |
| Transport ancillary to an enterprise’s main activity |
Examples include repair, maintenance and work-site activities. Quantities must not exceed 450 litres per packaging, including IBCs and large packagings, or the total limits in 1.1.3.6. Leakage must be prevented. Class 7 and transport for the enterprise’s supply or internal/external distribution are excluded. (ADR 1.1.3.1(c), Volume I, page 6.) |
| Emergency operations |
Exemptions cover necessary transport by or under the supervision of emergency-response authorities, including specified recovery operations, and emergency transport to save lives or protect the environment, subject to safe transport conditions. (ADR 1.1.3.1(d)–(e), Volume I, page 6.) |
| Certain empty, uncleaned fixed storage vessels |
Only specified previous contents qualify. Openings must be closed as required, leakage prevented and the vessels secured; vessels that contained desensitized explosives or substances prohibited from transport do not qualify. (ADR 1.1.3.1(f), Volume I, pages 6–7.) |
3. Small-load exemption per transport unit
ADR 1.1.3.6 is a partial exemption for carriage in packages, based on the transport category assigned in Table A, column (15) and the applicable quantity limits or mixed-load calculation. It is not a blanket exemption from ADR. (ADR 1.1.3.6.1–1.1.3.6.2, Volume I, page 9.)
It removes, among other requirements, Chapter 5.3 placarding/orange plates and Section 5.4.3 instructions in writing. However, specified transport-document, fire-extinguisher, training and operational requirements remain; security exemptions also have explicit Class 1 and Class 7 exceptions. (ADR 1.1.3.6.2, Volume I, page 9.)
4. Other specific exemptions
- Gases and fuel used for vehicle operation: exemptions exist for qualifying propulsion fuel and equipment-related gases—not automatically for fuel or gas carried as cargo. Liquid-fuel limits normally include 1,500 litres in fixed tanks per transport unit, 500 litres in a trailer-mounted tank and 60 litres in portable fuel receptacles; the provision includes an emergency-service exception and a combined fuel-energy limit. (ADR 1.1.3.2(a), Volume I, page 7; ADR 1.1.3.3(a), Volume I, page 8.)
- Empty, uncleaned packagings: packagings that contained goods of specified classes may be exempt only when appropriate measures eliminate all Class 1–9 hazards. Being empty alone is insufficient. (ADR 1.1.3.5, Volume I, page 9.)
- Electrical energy-storage/production devices: exemptions cover qualifying devices installed for vehicle propulsion or equipment operation, and devices in equipment used during transport. Cargo trackers and data loggers have a specific qualification referring to 5.5.4. (ADR 1.1.3.7, Volume I, page 11.)
- Refrigerants and conditioning agents: substances presenting only an asphyxiation hazard, when used for these purposes in vehicles or containers, remain subject to Section 5.5.3 rather than being completely unregulated. (ADR 1.1.3.9, Volume I, page 11.)
- Certain lamps containing dangerous goods: conditional exemptions exist, including for specified household collection/recycling movements, subject to the restrictions on radioactive material and mercury. (ADR 1.1.3.10, Volume I, page 11.)
Sources
- ADR 1.1.3.1 - Chapitre 1.1 - Exemptions related to the nature of the transport operation - 2412006_F_ECE_TRANS_352_Vol.I_WEB.pdf, page 6
- ADR 1.1.3.1(f); 1.1.3.2(a) - Chapitre 1.1 - Fixed storage vessels and vehicle fuel gases - 2412006_F_ECE_TRANS_352_Vol.I_WEB.pdf, page 7
- ADR 1.1.3.3; 1.1.3.4.1 - Chapitre 1.1 - Liquid fuel and product-specific exemptions - 2412006_F_ECE_TRANS_352_Vol.I_WEB.pdf, page 8
- ADR 1.1.3.4.3; 1.1.3.5; 1.1.3.6.1; 1.1.3.6.2 - Chapitre 1.1 - Excepted quantities, empty packagings and small-load exemptions - 2412006_F_ECE_TRANS_352_Vol.I_WEB.pdf, page 9
- ADR 1.1.3.7; 1.1.3.9; 1.1.3.10 - Chapitre 1.1 - Energy devices, refrigerants and lamps - 2412006_F_ECE_TRANS_352_Vol.I_WEB.pdf, page 11
- ADR 3.2.1 - Chapitre 3.2 - Table A, column (7b): excepted-quantity codes - 2412006_F_ECE_TRANS_352_Vol.I_WEB.pdf, page 275
- ADR 3.4.1 - Chapitre 3.4 - Limited quantities and retained requirements - 2412006_F_ECE_TRANS_352_Vol.I_WEB.pdf, page 643