No—standard combination packaging is not authorised for UN 1051, HYDROGEN CYANIDE, STABILIZED, containing less than 3% water. Table A assigns packing instruction P200, whose Table 3 specifies the permitted pressure-receptacle arrangements, rather than conventional inner packagings in an outer box or drum. (ADR 3.2, Table A, UN 1051, column (8), Volume I, page 316; ADR 4.1.4.1, P200, Table 3, Volume II, page 92.)
Two related restrictions are important:
- There is no limited-quantity or excepted-quantity alternative: the entry specifies 0 in column (7a) and E0 in column (7b). (ADR 3.2, Table A, UN 1051, Volume I, page 316.)
- MP2 prohibits packing UN 1051 together with other goods. This is a mixed-packing restriction, not the rule determining whether combination packaging is permitted; that decision comes from P200. (ADR 3.2, Table A, UN 1051, columns (8) and (9b), Volume I, page 316; ADR 4.1.10.4, MP2, Volume II, page 171.)